Home
Product
   ABB Analytical
   AMETEK P&AI
   NEO
   GENIE
   Perma-Pure
   LDETEK
   AII
   Extrel
   ADI
System
Careers
 
 
 

 

   
Single and Dual Path Monitor

Emission control systems for scrubber and abatement plants
Combustion control systems for boilers and waste incinerators
Slippage and emission control in deNOx plants (SCR and SNCR)
Explosion surveillance (safety systems) in chemical plants
Emission monitoring in Aluminum smelters or waste incinerators
Monitoring of vehicle exhaust

  Features
No gas sampling - in-situ measurement
Applicable for a wide range of process conditions

----------○High temperature (up to 1500 °C for some gases)
----------○High dust loads (> 100 g/m3 for short paths)
----------○Complex background gas mixtures, corrosive gases
Line measurement (integral concentration over the full stack diameter)
Low cost of ownership
Approved for ATEX zone 1 (EEx p) and zone 2 (EEx n)
Approved for CSA Class 1 Div 2 (non incendive)
German TUV approval for NH3+H2O
Open Path Monitor

Monitoring of production halls (e.g. Aluminum smelters)
Leak detection
Gas fencing in the proximity of industries
Fire protection (CO measurement)
Monitoring of traffic exhaust

  Features
Up to 1000 m measurement path
Zero cross interference from moisture (or other gases)
Unaffected by fog or rain down to <1% transmission
Low cost of ownership
Suitable for ATEX zone 1 (EEx p) and zone 2 (EEx n)
Suitable for CSA Class 1 Div 2 (non incendive)

Multipass Monitor

Trace measurements in pure gases
Low ppm H2S measurements (personnel protection)

  Features
Very low detection limits (ppb for most gases)
Offline gas analysis in controlled environment
Turn-key instrument
Low cost of ownership
Approved for ATEX zone 2 (EEx n)
Approved for CSA Class 1 Div 2 (non incendive)
Approved for CSA Class 1 Div 2 (non incendive)

SP Compact Monitor

●No gas sampling ?in-situ measurement
●Applicable for measurement across pipes down to 10 cm diameter
●Very low purge gas consumption (purge of optical windows)
●Line measurement (integral concentration over the full pipe diameter)
●Low cost of ownership
●Approved for ATEX zone 2 (EEx n)
 
Table of Principal Gases
O2 H2S Dual gas
HCl HCN NH3 + H2O
HF NO HF + H2O
NH3 N2O HCl + H2O
CO CH4 CO + CO2
CO2 C2H2 O2 + temp.
H2O C3H6 CO + H2O
* other gases available on request