Home
Product
   ABB Analytical
   AMETEK P&AI
   NEO
   GENIE
   Perma-Pure
   LDETEK
   AII
   Extrel
   ADI
System
Careers
 
 
80
 

 

   
  General Purpose PPB Oxygen Analyzers

GPR-1600UHP Oxygen Analyzer

State of the art proprietary UHP Pico-Ion sensor capable of oxygen analysis under 1 ppb and 18 month expected sensor life.  Sensitivity 0.5% FS range, Accuracy +/- 1%.  Fast recovery.  Sensor has no maintenance, or water to add.  Automatic ranging, Zero & Calibration.  Communication link USB.  Ranges- Standard: 0-100ppb, 0-1ppm, 0-10ppm, 0-100ppm.

  General Purpose PPM Oxygen Analyzers

GPR-1600MS Oxygen Analyzer

State of the art proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb and 36 month expected sensor life.  Sensor has no maintenance, or water to add.  Automated range, zero, calibration, data acquisition, system diagnostic functions.  Ranges- Standard: 0-1ppm, 0-10ppm, 0-100ppm, 0-1000ppm.

GPR-1600/ GPR-1600W Oxygen Analyzer

Proprietary Advanced Galvanic Sensor capable of oxygen analysis under 100ppb and 24 month expected sensor life.  Sensor has no maintenance, or water to add.  Automated range, zero, calibration, data acquisition, system diagnostic functions. Flow indicator and sample/bypass valves. Optional: 3 solenoid inlet valves control the introduction sample, span, zero gas to the analyzer enabling auto zero and calibration functions.  Ranges- Standard: 0-10ppm, 0-100ppm, 0-1000ppm, 0-1%, 0-25%.

  ATEX Explosion Proof PPM Oxygen Analyzers

GPR-18 ATEX PPM Explosion Proof Process O2 Analyzer

Proprietary Advanced Galvanic Sensor capable of oxygen analysis under 100ppb and 24 month expected sensor life.  Sensor has no maintenance, or water to add.  ATEX certified Ex D IIB+H2 T6, CE. (Class 1, Div. 1, Groups B, C, D) Wall mount configuration. Ranges- Standard: 0-10ppm, 0-100ppm, 0-1000ppm, 0-1%, 0-25%.


  ATEX Intrinsically Safe PPM Oxygen Analyzers

GPR-1800 AIS ATEX PPM Oxygen Transmitter

Proprietary Advanced Galvanic Sensor capable of oxygen analysis under 100ppb and 24 month expected sensor life.  Sensor has no maintenance, or water to add.  Intrinsically safe oxygen transmitter, ATEX  Ex II 2 G, Ex [ib] IIB T4, Tamb -20 deg. C to +50 deg. C. (Class 1, Division 1, Groups C, D)  Ranges- Standard: 0-10ppm, 0-100pp, 0-1000ppm, 0-1%, 0-25%.

GPR-1800AIS Oxygen Transmitter (Shown with optional H2S sample system)

GPR-1800AIS Oxygen Transmitter (No sample system)
  PPM Portable Oxygen Analyzers

GPR-1200 ppm Oxygen Analyzer

Proprietary Advanced Galvanic Sensor capable of oxygen analysis under 100ppb and 24 month expected sensor life.  Sensor has no maintenance, or water to add.  Meets recognized intrinsic safety (ATEX approval pending) standards for use in Class 1, Division 1, Groups C, D hazardous areas.  Integral stainless steel bypass sample system not only extends sensor life but significantly increases operator productivity.  Ranges- Standard: 0-10ppm, 0-100ppm, 0-1000ppm, 0-1%, 0-25%.

  General Purpose Percent Oxygen Analyzers

 

 

GPR-2600/ GPR-2600W

Oxygen Analyzer

Proprietary Advanced Galvanic Sensor capable of oxygen analysis from 0.05% to 100% and 36 month expected sensor life. Sensor has no maintenance, or water to add. Automated range, zero, calibration, data acquisition, system diagnostic functions. Flow control, flow indicator. Ranges- Standard: 0-1%, 0-5%, 0-10%, 0-25%.

GPR-1800AIS Oxygen Transmitter (Shown with optional H2S sample system)

 

GPR-1800AIS Oxygen Transmitter (No sample system)

 

  ATEX Explosion Proof Percent Oxygen Analyzers

GPR-28 ATEX Explosion Proof Process O2 Analyzer

Proprietary Advanced Galvanic Sensor capable of oxygen analysis from 0.05% to 100% and 36 months expected sensor life. Sensor has no maintenance, or water to add.  ATEX certified Ex D IIB+H2 T6, CE. (Class 1, Div. 1, Groups B, C, D) Wall mount configuration.  Ranges- Standard: 0-1%, 0-5%, 0-10%, 0-25% FS ranges.

  ATEX Intrinsically Safe Percent Oxygen Analyzers

GPR-2800 AIS ATEX Percent Oxygen Analyzer

Proprietary Advanced Galvanic Sensor capable of oxygen analysis from 0.05% to 100% and 36 month expected sensor life. Sensor has no maintenance, or water to add.  Automated range, zero, calibration, data acquisition, system diagnostic functions.  Intrinsically safe oxygen transmitter, ATEX  Ex II 2 G, Ex [ib] IIB T4, Tamb -20 deg. C to +50 deg. C. (Class 1, Division 1, Groups C, D)  Ranges- 0-1%, 0-5%, 0-10%, 0-25% FS ranges.

GPR-2800AIS Oxygen Transmitter (Shown with Optional Sample System)

 

GPR-2800AIS O2 Transmitter (No sample System)

19F-9, No.79, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, Taiwan R.O.C. TEL:(02)2698-4762 FAX:(02)2698-4763 Copyright © Kinetic systems Corp. All Rights Reserved