-One central unit and various analyzer modules
--•with common controls
--•with a common connection technology
--•in a common system housing
-analyzer modules with different measurement
-principles for all process and emissions monitoring
-applications
-Multiple analyzer systems with up to four analyzer
-modules handling a total of six sample components
-Extensive automatic calibration with air or integral
-calibration cell eliminating the need for test gas
-cylinders
-"Safety Concept" for measuring flammable gases in
-Zone 2 and for measuring corrosive and toxic gases
-Simultaneous digital and analog display of
-measured values on a large graphics panel
-Menu-driven operator interface
-Clear-text status messages
-Multiple interfaces for communication with host and
-associated systems
-Flexibly configurable analog and digital inputs and
-outputs on various input/output modules
-Optional integrated pneumatics modules
-Housing design for 19-inch rack mounting (Model
-AO2020) or wall mounting (Model AO2040)
-Modular design for ease of service
-Self-mounting function indicates when maintenance
-is required |
|
EL3060 Series Gas Analyzer
-The specialists for hazardous locations
-Well-proven measurement technology
|
|
URAS14
The continuous NDIR industrial photometer can selectively measure concentrations of up to four sample components
Typical applications
-Emission monitoring
-Landfill gas monitoring
-Gas production/purity monitoring
-Burner optimization
-Process monitoring, e.g. in the chemical industry, steel
-and glass industry, power generation
-Fermentation process monitoring
-Blast furnace gas analysis |
|
Typical applications
-Burner optimization
-Control of DeNOx installations
-Emission monitoring of FCC furnaces
-Nitric acid production
-Cement production
-Purity measurement in the chemical industry
-Production and processing of cellulose and viscose
-Natural gas conditioning
-Cl2 production and processing
-Plastics production
-Phosgene production processes |
|
Caldos15
The Caldos15 is design for highly corrosive application. The measuring cell with its glass-coated resistor is especially resistant to corrosive gases. With Caldos15 pressure correction is not required. The measurement signal is completely independent of the sample gas pressure-whether negative or positive.
|
|
Caldos17
Smallest measuring ranges and fast measurements are characteristic of Caldos17 thanks to its silicon sensor. In addition, the micro-structure of the sensor gives the Caldos17 a particularly short T90 response time. Measuring ranges can be selected freely. An exceptionally long-term stability of the end point permits Caldos17 the single-point calibration with only one gas.. |
|
Magnos16
The Magnos16 is based on the magneto-mechanical measuring principle. Thanks to the short T90 time, the Magnos16 is also suitable for measuring rapid changes in the concentration of the sample gas. |
|
Magnos17
The Magnos17 is based on the thermomagnetical measuring principle. The robust measuring cell means that the Magnos17 is especially resistant to vibrations and shocks. |
|
Flame ionization detectors
Typical applications
-Emission monitoring
-Process monitoring
-Measurement of volatile hydrocarbons (VOC) in water
-Purity measurements of O2, N2 and argon |